SparkQuote NEC calculators

by FastDrop

MCP Verified 1 hour ago Registry import free

NEC 2023 electrical calculators: wire size, ampacity, voltage drop, conduit fill, box fill, load.

NEC 2023 electrical calculators: wire size, ampacity, voltage drop, conduit fill, box fill, load. Official MCP Registry: ai.sparkquote/nec-calculators@1.0.0. Remote endpoint: https://sparkquote.ai/mcp

Problem it solves

Discoverable MCP server listed in the official MCP Registry.

How it's different

Remote MCP endpoint ingested from the official registry and probed by FastDrop.

Ingested from the official MCP Registry

FastDrop pulled this entry from the official MCP Registry as ai.sparkquote/nec-calculators and probed the endpoint. The maker did not submit it, so the outbound link is not endorsed and the description is not theirs.

If this is your server, claim the listing to edit it and take ownership. The registry index lists everything else still awaiting a probe.

Claim this listing

Tools this endpoint exposes

Read directly from the endpoint on 14 Oct 2026. Not supplied by the maker.

  • wire_size

    Minimum conductor size for a circuit: NEC Table 310.16 ampacity at the termination temperature rating, the 240.4(D) small-conductor limits, voltage drop over the run, and the Table 250.122 equipment g

  • voltage_drop

    Voltage drop for a given conductor size, current and one-way length, single- or three-phase, from NEC Chapter 9 Table 8 circular mils (VD = 2·K·I·L / CM, or √3 for three-phase).

  • watts_to_amps

    Current drawn by a load in watts at a voltage and power factor, single- or three-phase, plus the 125% continuous-load value.

  • conduit_fill

    Percent fill and maximum number of THHN/THWN-2 conductors of one size in EMT or PVC Schedule 40, from NEC Chapter 9 Tables 1, 4 and 5.

  • box_fill

    Minimum outlet box volume from NEC 314.16(B): conductor, device (2 each), clamp and grounding allowances times the Table 314.16(B) volume for the largest conductor.

  • load_calculator

    Dwelling service load by the NEC 220.82 optional method: 3 VA/ft² lighting, small-appliance and laundry circuits, fixed appliances, demand factor, heating or cooling, and the minimum standard service

  • ohms_law

    Ohm's law and power: give exactly two of voltage, current, resistance and power; the other two are calculated.

  • panel_schedule

    Lays circuits out on a 120/240 V single-phase or 208Y/120 V three-phase panel and totals the load per phase with the imbalance.

Is this tool yours?

Claim this listing and we’ll verify ownership before handing it over.

Sign in to claim this listing

Matched on shared tags and the tools their MCP servers actually expose.

Reviews

Sign in to leave a review.

No reviews yet.

Comments

Sign in to join the discussion.

No comments yet - start the discussion.